lab report

    Experiment 2: Concentration Gradients and Membrane Permeability
    In this experiment you will dialyze a solution of glucose and starch to observe:
    An indicator is a substance that changes color when in the presence of a specific substance. In this experiment IKI will be used as an indicator to test for the presence of starch.
    Materials
    (5) 100 mL Beakers
    10 mL 1% Glucose Solution C6H12O6
    4 Glucose Test Strips
    (1) 100 mL Graduated Cylinder
    4 mL 1% Iodine-Potassium Iodide IKI
    5 mL Liquid Starch C6H10O5
    3 Pipettes
    4 Rubber Bands (Small; contain latex handle with gloves on if allergic)
    Permanent Marker
    *Stopwatch
    *Water
    *Scissors
    *15.0 cm Dialysis Tubing
    *You Must Provide
    *Be sure to measure and cut only the length you need for this experiment. Reserve the remainder for later experiments.
    Attention!
    Do not allow the open end of the dialysis tubing to fall into the beaker. If it does remove the tube and rinse thoroughly with water before refilling it with the starch/glucose solution and replacing it in the beaker.
    Note:
    If you make a mistake the dialysis tubing can be rinsed and used again.
    Dialysis tubing must be soaked in water before you will be able to open it up to create the dialysis bag. Follow these directions for this experiment:
    1. Soak the tubing in a beaker of water for ten minutes.
    2. Place the dialysis tubing between your thumb and forefinger and rub the two digits together in a shearing manner. This motion should open up the tube so that you can fill it with the different solutions.
    Procedure
    1. Measure and pour 50 mL of water into a 100 mL beaker using the 100 mL graduated cylinder. Cut a piece of dialysis tubing 15.0 cm long. Submerge the dialysis tubing in the water for at least ten minutes.
    2. Measure and pour 82 mL of water into a second 100 mL beaker using the 100 mL graduated cylinder. This is the beaker you will put the filled dialysis bag into in Step 9.
    3. Make the glucose/sucrose mixture. Use a graduated pipette to add 5 mL of glucose solution to a third 100 mL beaker and label it dialysis bag solution. Use a different graduated pipette to add 5 mL of starch solution to the same beaker. Mix by pipetting the solution up and down six times.
    4. Using the same pipette that you used to mix the dialysis bag solution remove 2 mL of the dialysis bag solution and place it in a clean beaker. This sample will serve as your positive control for glucose and starch.
    a. Dip one of the glucose test strips into the 2 mL of glucose/starch solution in the third beaker. After one minute has passed record the final color of the glucose test strip in Table 3. This is your positive control for glucose.
    b. Use a pipette to transfer approximately 0.5 mL of IKI into the 2 mL of glucose/starch solution into the third beaker. After one minute has passed record the final color of the glucose/starch solution in the beaker in Table 3. This is your positive control for starch.
    5. Using a clean pipette remove 2 mL of water from the 82 mL of water you placed in a beaker in Step 2 and place it in a clean beaker. This sample will serve as your negative controls for glucose and starch.
    a. Dip one of the glucose test strips into the 2 mL of water in the beaker. After one minute has passed record the final color of the glucose test strip in Table 3. This is your negative control for glucose.
    b. Use a pipette to transfer approximately 0.5 mL of IKI into the 2 mL in the beaker. After one minute has passed record the final color of the water in the beaker in Table 3. This is your negative control for starch.
    Note:The color results of these controls determine the indicator reagent key. You must use these results to interpret the rest of your results.
    6. After at least ten minutes have passed remove the dialysis tube and close one end by folding over 3.0 cm of one end (bottom). Fold it again and secure with a rubber band (use two rubber bands if necessary).
    7. Test to make sure the closed end of the dialysis tube will not allow solution to leak out. Dry off the outside of the dialysis tube bag with a cloth or paper towel. Then add a small amount of water to the bag and examine the rubber band seal for leakage. Be sure to remove the water from the inside of the bag before continuing.
    Figure 4:Step 9 reference.
    9. Place the filled dialysis bag in the 100 mL beaker filled with 80 mL of water leaving the open end draped over the edge of the beaker as shown in Figure 4.
    10.Allow the solution to sit for 60 minutes. Clean and dry all materials except the beaker holding the dialysis bag.
    11.After the solution has diffused for 60 minutes remove the dialysis bag from the beaker and empty the contents of the bag into a clean dry beaker. Label the beaker final dialysis bag solution.
    12.Test the final dialysis bag solution for the presence of glucose by dipping one glucose test strip into the dialysis bag. Wait one minute before reading the results of the test strip. Record your results for the presence of glucose in Table 4.
    13.Test for the presence of starch by adding 2 mL IKI. After one minute has passed record the final color in Table 4.
    14.Use a pipette to transfer 8 mL of the water in the beaker to a clean beaker. Test the beaker water for the presence of glucose by dipping one glucose test strip into the beaker. Wait one minute before reading the results of the test strip and record the results in Table 4.
    15.Test for the presence of starch by adding 2 mL of IKI to the beaker water. Record the final color of the beaker solution in Table 4.
    Table 3: Indicator Reagent Data
    Indicator
    Starch Positive
    Control (Color)
    Starch Negative
    Control (Color)
    Glucose Positive
    Control (Color)
    Glucose Negative
    Control (Color)
    Glucose Test Strip
    n/a
    n/a
    IKI Solution
    n/a
    n/a
    Table 4: Diffusion of Starch and Glucose Over Time
    Indicator
    Dialysis Bag After 60 Minutes
    Beaker Water After 60 Minutes
    IKI Solution
    Glucose Test Strip
    Post-Lab Questions
    1. Why is it necessary to have positive and negative controls in this experiment?
    2. Draw a diagram of the experimental set-up. Use arrows to depict the movement of each substance in the dialysis bag and the beaker.
    3. Which substance(s) crossed the dialysis membrane? Support your response with data-based evidence.
    4. Which molecules remained inside of the dialysis bag?
    5. Did all of the molecules diffuse out of the bag into the beaker? Why or why not?
    Experiment 1: Diffusion through a Liquid
    In this experiment you will observe the effect that different molecular weights have on the ability of dye to travel through a viscous medium.
    Materials
    1 60 mL Corn Syrup Bottle C12H22O11
    Red and Blue Dye Solutions (Blue molecular weight = 793 g/mole; red molecular weight = 496 g/mole)
    (1) 9 cm Petri Dish (top and bottom halves)
    Ruler
    *Stopwatch
    *Clear Tape
    *You Must Provide
    Procedure
    1. Use clear tape to secure one-half of the petri dish (either the bottom or the top half) over a ruler. Make sure that you can read the measurement markings on the ruler through the petri dish. The dish should be positioned with the open end of the dish facing upwards.
    Table 1: Rate of Diffusion in Corn Syrup
    Time (sec)
    Blue Dye
    Red Dye
    Time (sec)
    Blue Dye
    Red Dye
    10
    70
    20
    80
    30
    90
    40
    100
    50
    110
    60
    120
    Table 2: Speed of Diffusion of Different Molecular Weight Dyes
    Structure
    Molecular Weight
    Total Distance
    Traveled (mm)
    Speed of Diffusion
    (mm/hr)*
    Blue Dye
    Red Dye
    *Multiply the total distance diffused by 30 to get the hourly diffusion rate
    Post-Lab Questions
    https://nuonline.neu.edu/bbcswebdav/pid-9451339-dt-content-rid-14232100_1/courses/BIO1101.90155.201714/BIO1101.90155.201714_ImportedContent_20160930044714/CourseRoot/html/lab006s001.html
    https://nuonline.neu.edu/bbcswebdav/pid-9451340-dt-content-rid-14232401_1/courses/BIO1101.90155.201714/BIO1101.90155.201714_ImportedContent_20160930044714/CourseRoot/html/lab006s002.html
    https://nuonline.neu.edu/bbcswebdav/pid-9451341-dt-content-rid-14232402_1/courses/BIO1101.90155.201714/BIO1101.90155.201714_ImportedContent_20160930044714/CourseRoot/html/lab006s003.html

                                                                                                                                      Order Now